﻿<!DOCTYPE html PUBLIC "-//W3C//DTD XHTML 1.0 Transitional//EN" "http://www.w3.org/TR/xhtml1/DTD/xhtml1-transitional.dtd">
<html xmlns="http://www.w3.org/1999/xhtml">
<head>
<meta http-equiv="Content-Type" content="text/html; charset=utf-8" />
<title>BTL检测集团</title>
<meta name="keywords" content="Inspection、certification" />
<meta name="description" content="BTL electronic product testing and certification, providing electronic product certification services in many regions at home and abroad.  " />
<meta name="viewport" content="width=1100,target-densitydpi=high-dpi,user-scalable=yes"/>
<link rel="stylesheet" type="text/css" href="css/css.css">
<link rel="stylesheet" type="text/css" href="css/banner.css">
<link rel="stylesheet" type="text/css" href="css/animate.min.css">
<script language="JavaScript" type="text/JavaScript" src="js/jquery-1.7.1.min.js"></script>
<script language="JavaScript" type="text/javascript" src="js/banner.js"></script>
<script language="JavaScript" type="text/JavaScript" src="js/images.js"></script>
<script language="JavaScript" type="text/JavaScript" src="js/clearbox.js"></script>
<script language="JavaScript" type="text/JavaScript" src="js/wow.min.js"></script> 
<script>
function uaredirect(f){
	try{
		var b=false;
		if(arguments[1]){
			var e=window.location.host;var a=window.location.href;
			if(isSubdomain(arguments[1],e)==1){
				f=f+"/#m/"+a;b=true
			}else{
				if(isSubdomain(arguments[1],e)==2){
					f=f+"/#m/"+a;b=true
				}else{
					f=a;b=false
				}
			}
		}else{
			b=true
		}
		if(b){
			var c=window.location.hash;
			if(!c.match("fromapp")){
				if((navigator.userAgent.match(/(iPhone|iPod|Android|ios|iPad)/i))){
					location.replace(f)
				}
			}
		}
	}catch(d){}
}
uaredirect('men/industryshow.php?id=760');

wow = new WOW({animateClass: 'animated',offset:100}); 
wow.init();
$(document).ready(function(){
  $(".menu li").hover(function(){
  	$("div",this).fadeIn();
  },function(){
  	$("div",this).fadeOut();
  });
  $(".menu2 ul li").hover(function(){
  	$("div",this).fadeIn();
  },function(){
  	$("div",this).fadeOut();
  });
});
</script>
</head>
<body>
<div class="toper">
	<div class="topcen">
    <form name="topform" method="post" action="serach.php">
    	<input type="text" name="topword" value="" class="topinp" />
        <input type="submit" name="topsub" value="" class="topsub" />
    </form>
	<span class="language"><a href="cn/index.php">简</a> | <a href="ft/index.php">繁</a> | <a href="index.php" >EN</a></span>
	<div class="fl logoer"><a href="index.php" ><img src="images/logo.png"></a></div>
    <ul class="menu">
        <li><a href="product.php" class="m">Service Center</a>
    	<div>
        	<a href=product.php?cid=477>NCC RCB</a>        </div>
    </li>
        <li><a href="industry.php" class="m">Technical platform</a>
    	<div>
        	<a href=industry.php?cid=473>Mobile Communication</a><a href=industry.php?cid=479>BQB</a><a href=industry.php?cid=472>SAR / OTA</a><a href=industry.php?cid=480>IoT</a><a href=industry.php?cid=413>EMC</a><a href=industry.php?cid=424>RF</a><a href=industry.php?cid=474>Telecom</a><a href=industry.php?cid=425>Safety</a><a href=industry.php?cid=485>New Energy</a><a href=industry.php?cid=481>Other</a><a href=industry.php?cid=486>Information security</a>        </div>
    </li>
        <li><a href="zhengshu.php" class="m">Certificate</a>
    	<div>
        	<a href=zhengshu.php?cid=444>Certificate</a>        </div>
    </li>
        <li><a href="about.php" class="m">About BTL</a>
    	<div>
        	<a href=about.php?id=487>Group Profile</a><a href=about.php?id=73>Complaints process</a><a href=about.php?id=237>Declaration of impartiality</a>        </div>
    </li>
        <li><a href="join.php" class="m">Join us</a>
    	<div>
        	<a href=join.php?cid=428>Talent recruitment</a><a href=join.php?cid=429>Employees demeanor</a><a href=join.php?cid=449>The enterprise information</a>        </div>
    </li>
        
    </ul>
    </div>
    <div class="menu2">
    	<ul>
        <li>Global market access: </li>
		        <li><a href="global.php?cid=416" class="m">East Asia & South Asia</a>
        	<div>
            	<a href=news.php?cid=440>China</a><a href=news.php?cid=456>Japan</a><a href=news.php?cid=458>Indian</a><a href=news.php?cid=459>Korea</a><a href=news.php?cid=460>Taiwan</a>            </div>
        </li>
                <li><a href="global.php?cid=417" class="m">Southeast Asia</a>
        	<div>
            	<a href=news.php?cid=433>Indonesia</a><a href=news.php?cid=434>Malaysia</a><a href=news.php?cid=435>Thailand</a><a href=news.php?cid=436>Vietnam</a>            </div>
        </li>
                <li><a href="global.php?cid=418" class="m">Middle East</a>
        	<div>
            	<a href=news.php?cid=461>Saudi Arabia</a>            </div>
        </li>
                <li><a href="global.php?cid=419" class="m">Africa</a>
        	<div>
            	<a href=news.php?cid=463>South Africa</a>            </div>
        </li>
                <li><a href="global.php?cid=420" class="m">Europe</a>
        	<div>
            	<a href=news.php?cid=465>European Union</a><a href=news.php?cid=484>United Kingdom</a><a href=news.php?cid=464>Russia</a>            </div>
        </li>
                <li><a href="global.php?cid=421" class="m">South America</a>
        	<div>
            	<a href=news.php?cid=469>Argentina</a><a href=news.php?cid=470>Brazil</a>            </div>
        </li>
                <li><a href="global.php?cid=422" class="m">North America</a>
        	<div>
            	<a href=news.php?cid=466>USA</a><a href=news.php?cid=467>Canada</a><a href=news.php?cid=468>Mexico</a>            </div>
        </li>
                </ul>
    </div>
</div>
<div class="bgw">

<div class="m2pos">
 <div class="main"><span class="m2posNm">Location：<a href='index.php'>Home</a> - Technical platform - Overview of EN IEC 61000-4-29:2026</span></div>
 </div>
 <div class="p50">



 
 <div class="m2proBox" style="border-bottom:0;">
<div class="main clear"><div class="lyleft">
    	<ul>
		<li><a href=industry.php?cid=473 class=>Mobile Communication</a></li><li><a href=industry.php?cid=479 class=>BQB</a></li><li><a href=industry.php?cid=472 class=>SAR / OTA</a></li><li><a href=industry.php?cid=480 class=>IoT</a></li><li><a href=industry.php?cid=413 class=cur>EMC</a></li><li><a href=industry.php?cid=424 class=>RF</a></li><li><a href=industry.php?cid=474 class=>Telecom</a></li><li><a href=industry.php?cid=425 class=>Safety</a></li><li><a href=industry.php?cid=485 class=>New Energy</a></li><li><a href=industry.php?cid=481 class=>Other</a></li><li><a href=industry.php?cid=486 class=>Information security</a></li>        </ul>
    </div>
    <div class="lyright">
<div class="pp2">
<div class="tt">Overview of EN IEC 61000-4-29:2026</div>
<div class="txt2 txtimg"><p><strong style="color: rgb(0, 176, 240);">1.&nbsp;</strong><strong style="color: rgb(0, 176, 240);">Standard Title and Purpose</strong></p><p><strong>EN IEC 61000-4-29:2026</strong></p><p><strong>Electromagnetic compatibility (EMC) – Part 4-29: Testing and measurement techniques – Voltage dips, short interruptions and voltage variations on d.c. input power port immunity tests.</strong></p><p>This standard is intended to evaluate the immunity of equipment with <strong>DC input power ports</strong> when subjected to the following DC power disturbances:</p><table cellspacing="0" cellpadding="0"><tbody><tr style=";height:23px" class="firstRow"><td width="166" valign="middle" style="border: 1px solid windowtext; background: rgb(0, 112, 192); padding: 0px 7px; word-break: break-all;" align="center"><p><span style="color: rgb(255, 255, 255);"><strong>Test item</strong></span></p></td><td width="618" valign="middle" style="border-width: 1px 1px 1px medium; border-style: solid solid solid none; border-color: windowtext windowtext windowtext currentcolor; border-image: initial; background: rgb(0, 112, 192); padding: 0px 7px; word-break: break-all;" align="center"><p><span style="color: rgb(255, 255, 255);"><strong>Description</strong></span></p></td></tr><tr><td width="160" style="border-width: medium 1px 1px; border-style: none solid solid; border-color: currentcolor windowtext windowtext; border-image: initial; padding: 0px 7px; word-break: break-all;" align="center" valign="middle"><p>Voltage dips</p></td><td width="612" style="border-width: medium 1px 1px medium; border-style: none solid solid none; border-color: currentcolor windowtext windowtext currentcolor; padding: 0px 7px; word-break: break-all;"><p>A temporary reduction of the DC supply voltage, for example from 100% rated voltage to 70%, 40%, or lower.</p></td></tr><tr><td width="166" style="border-width: medium 1px 1px; border-style: none solid solid; border-color: currentcolor windowtext windowtext; border-image: initial; background: rgb(218, 233, 247); padding: 0px 7px; word-break: break-all;" align="center" valign="middle"><p>Short interruptions</p></td><td width="618" style="border-width: medium 1px 1px medium; border-style: none solid solid none; border-color: currentcolor windowtext windowtext currentcolor; background: rgb(218, 233, 247); padding: 0px 7px; word-break: break-all;"><p>A temporary interruption of the DC supply voltage, close to 0 V.</p></td></tr><tr><td width="166" style="border-width: medium 1px 1px; border-style: none solid solid; border-color: currentcolor windowtext windowtext; border-image: initial; padding: 0px 7px; word-break: break-all;" align="center" valign="middle"><p>Voltage variations</p></td><td width="618" style="border-width: medium 1px 1px medium; border-style: none solid solid none; border-color: currentcolor windowtext windowtext currentcolor; padding: 0px 7px; word-break: break-all;"><p>A gradual or temporary increase or decrease of DC voltage over a defined period, simulating battery operation, backup power switching, or DC network variation.</p></td></tr></tbody></table><p>&nbsp;</p><p><span style="color: rgb(0, 176, 240);"></span></p><hr/><p><span style="color: rgb(0, 176, 240);"><strong>2. Scope of Application</strong></span><br/></p><p>EN IEC 61000-4-29 applies to electrical and electronic equipment with a DC input power port, especially equipment powered by an external DC network or DC power distribution system.</p><p>Typical applicable products include:</p><table cellspacing="0" cellpadding="0"><tbody><tr class="firstRow"><td width="360" valign="middle" style="border: 1px solid windowtext; background: rgb(0, 112, 192); padding: 0px 7px; word-break: break-all;" align="center"><p><span style="color: rgb(255, 255, 255);"><strong>Product / System</strong></span></p></td><td width="450" valign="middle" style="border-width: 1px 1px 1px medium; border-style: solid solid solid none; border-color: windowtext windowtext windowtext currentcolor; border-image: initial; background: rgb(0, 112, 192); padding: 0px 7px; word-break: break-all;" align="center"><p><span style="color: rgb(255, 255, 255);"><strong>Applicable situation</strong></span></p></td></tr><tr><td width="354" valign="middle" style="border-width: medium 1px 1px; border-style: none solid solid; border-color: currentcolor windowtext windowtext; border-image: initial; padding: 0px 7px; word-break: break-all;" align="center"><p>Industrial control equipment</p></td><td width="450" valign="top" style="border-width: medium 1px 1px medium; border-style: none solid solid none; border-color: currentcolor windowtext windowtext currentcolor; padding: 0px 7px; word-break: break-all;"><p>24 Vdc or 48 Vdc control power input</p></td></tr><tr><td width="360" valign="middle" style="border-width: medium 1px 1px; border-style: none solid solid; border-color: currentcolor windowtext windowtext; border-image: initial; background: rgb(218, 233, 247); padding: 0px 7px; word-break: break-all;" align="center"><p>Telecom and network equipment</p></td><td width="450" valign="top" style="border-width: medium 1px 1px medium; border-style: none solid solid none; border-color: currentcolor windowtext windowtext currentcolor; background: rgb(218, 233, 247); padding: 0px 7px; word-break: break-all;"><p>-48 Vdc telecom power systems</p></td></tr><tr><td width="354" valign="middle" style="border-width: medium 1px 1px; border-style: none solid solid; border-color: currentcolor windowtext windowtext; border-image: initial; padding: 0px 7px; word-break: break-all;" align="center"><p>Data center DC-powered equipment</p></td><td width="444" valign="top" style="border-width: medium 1px 1px medium; border-style: none solid solid none; border-color: currentcolor windowtext windowtext currentcolor; padding: 0px 7px; word-break: break-all;"><p>380 Vdc, 400 Vdc, 800 Vdc, or other DC distribution systems</p></td></tr><tr><td width="360" valign="middle" style="border-width: medium 1px 1px; border-style: none solid solid; border-color: currentcolor windowtext windowtext; border-image: initial; background: rgb(218, 233, 247); padding: 0px 7px; word-break: break-all;" align="center"><p>Railway, vehicle, or power equipment</p></td><td width="450" valign="top" style="border-width: medium 1px 1px medium; border-style: none solid solid none; border-color: currentcolor windowtext windowtext currentcolor; background: rgb(218, 233, 247); padding: 0px 7px; word-break: break-all;"><p>DC auxiliary power input</p></td></tr><tr><td width="360" valign="middle" style="border-width: medium 1px 1px; border-style: none solid solid; border-color: currentcolor windowtext windowtext; border-image: initial; padding: 0px 7px; word-break: break-all;" align="center"><p>Battery-powered or energy storage equipment</p></td><td width="450" valign="top" style="border-width: medium 1px 1px medium; border-style: none solid solid none; border-color: currentcolor windowtext windowtext currentcolor; padding: 0px 7px; word-break: break-all;"><p>Battery switching, charge/discharge conditions, or backup power switching</p></td></tr></tbody></table><p>&nbsp;</p><hr/><p><strong><span style="color: rgb(0, 176, 240);">3. Difference from IEC 61000-4-11 and IEC 61000-4-34</span></strong><br/></p><table cellspacing="0" cellpadding="0"><tbody><tr class="firstRow"><td width="160" valign="middle" style="border: 1px solid windowtext; background: rgb(0, 112, 192); padding: 0px 7px; word-break: break-all;" align="center"><p><span style="color: rgb(255, 255, 255);"><strong>Standard</strong></span></p></td><td width="95" valign="middle" style="border-width: 1px 1px 1px medium; border-style: solid solid solid none; border-color: windowtext windowtext windowtext currentcolor; border-image: initial; background: rgb(0, 112, 192); padding: 0px 7px; word-break: break-all;" align="center"><p><span style="color: rgb(255, 255, 255);"><strong>Power type</strong></span></p></td><td width="469" valign="middle" style="border-width: 1px 1px 1px medium; border-style: solid solid solid none; border-color: windowtext windowtext windowtext currentcolor; border-image: initial; background: rgb(0, 112, 192); padding: 0px 7px; word-break: break-all;" align="center"><p><span style="color: rgb(255, 255, 255);"><strong>Application</strong></span></p></td></tr><tr><td width="160" valign="middle" style="border-width: medium 1px 1px; border-style: none solid solid; border-color: currentcolor windowtext windowtext; border-image: initial; padding: 0px 7px;" align="center"><p>IEC/EN &nbsp; 61000-4-11</p></td><td width="95" valign="middle" style="border-width: medium 1px 1px medium; border-style: none solid solid none; border-color: currentcolor windowtext windowtext currentcolor; padding: 0px 7px;" align="center"><p>AC</p></td><td width="463" valign="top" style="border-width: medium 1px 1px medium; border-style: none solid solid none; border-color: currentcolor windowtext windowtext currentcolor; padding: 0px 7px; word-break: break-all;"><p>Voltage dips, short interruptions, and voltage variations for AC equipment with input current up to 16 A per phase.</p></td></tr><tr><td width="160" valign="middle" style="border-width: medium 1px 1px; border-style: none solid solid; border-color: currentcolor windowtext windowtext; border-image: initial; background: rgb(218, 233, 247); padding: 0px 7px;" align="center"><p>IEC/EN 61000-4-34</p></td><td width="95" valign="middle" style="border-width: medium 1px 1px medium; border-style: none solid solid none; border-color: currentcolor windowtext windowtext currentcolor; background: rgb(218, 233, 247); padding: 0px 7px;" align="center"><p>AC</p></td><td width="463" valign="top" style="border-width: medium 1px 1px medium; border-style: none solid solid none; border-color: currentcolor windowtext windowtext currentcolor; background: rgb(218, 233, 247); padding: 0px 7px; word-break: break-all;"><p>Voltage dips, short interruptions, and voltage variations for AC equipment with input current greater than 16 A per phase.</p></td></tr><tr><td width="160" valign="middle" style="border-width: medium 1px 1px; border-style: none solid solid; border-color: currentcolor windowtext windowtext; border-image: initial; padding: 0px 7px;" align="center"><p>IEC/EN &nbsp; 61000-4-29</p></td><td width="95" valign="middle" style="border-width: medium 1px 1px medium; border-style: none solid solid none; border-color: currentcolor windowtext windowtext currentcolor; padding: 0px 7px;" align="center"><p>DC</p></td><td width="469" valign="top" style="border-width: medium 1px 1px medium; border-style: none solid solid none; border-color: currentcolor windowtext windowtext currentcolor; padding: 0px 7px; word-break: break-all;"><p>Voltage dips, short interruptions, and voltage variations for DC</p><p>input power ports.</p></td></tr></tbody></table><p>In simple terms, IEC 61000-4-11 and IEC 61000-4-34 are used for AC power ports, while IEC 61000-4-29 is used for DC input power ports.</p><p>&nbsp;</p><p><strong><span style="color: rgb(0, 176, 240);"></span></strong></p><hr/><p><strong><span style="color: rgb(0, 176, 240);">4. Main Changes Expected in the 2026 Edition</span></strong><br/></p><p>Compared with the 2000 edition, the 2026 edition is expected to be a technical revision. The main changes are summarized below:</p><table cellspacing="0" cellpadding="0"><tbody><tr class="firstRow"><td width="258" valign="middle" style="border: 1px solid windowtext; background: rgb(0, 112, 192); padding: 0px 7px; word-break: break-all;" align="center"><p><strong><span style="color: rgb(255, 255, 255);">Change item</span></strong></p></td><td width="250" valign="middle" style="border-width: 1px 1px 1px medium; border-style: solid solid solid none; border-color: windowtext windowtext windowtext currentcolor; border-image: initial; background: rgb(0, 112, 192); padding: 0px 7px; word-break: break-all;" align="center"><p><strong><span style="color: rgb(255, 255, 255);">Description</span></strong></p></td><td width="251" valign="middle" style="border-width: 1px 1px 1px medium; border-style: solid solid solid none; border-color: windowtext windowtext windowtext currentcolor; border-image: initial; background: rgb(0, 112, 192); padding: 0px 7px; word-break: break-all;" align="center"><p><strong><span style="color: rgb(255, 255, 255);">Practical impact</span></strong></p></td></tr><tr><td width="264" style="border-width: medium 1px 1px; border-style: none solid solid; border-color: currentcolor windowtext windowtext; border-image: initial; padding: 0px 7px; word-break: break-all;"><p>Increased output voltage capability of the test generator</p></td><td width="250" style="border-width: medium 1px 1px medium; border-style: none solid solid none; border-color: currentcolor windowtext windowtext currentcolor; padding: 0px 7px; word-break: break-all;"><p>To address new DC network</p><p>voltages</p></td><td width="257" style="border-width: medium 1px 1px medium; border-style: none solid solid none; border-color: currentcolor windowtext windowtext currentcolor; padding: 0px 7px; word-break: break-all;"><p>More relevant for high-voltage DC systems such as 380 Vdc, 400 Vdc, or 800 Vdc equipment</p></td></tr><tr><td width="264" style="border-width: medium 1px 1px; border-style: none solid solid; border-color: currentcolor windowtext windowtext; border-image: initial; background: rgb(218, 233, 247); padding: 0px 7px; word-break: break-all;"><p>Added tolerance for voltage variation duration</p></td><td width="250" style="border-width: medium 1px 1px medium; border-style: none solid solid none; border-color: currentcolor windowtext windowtext currentcolor; background: rgb(218, 233, 247); padding: 0px 7px; word-break: break-all;"><p>Clarifies the tolerance of test</p><p>duration</p></td><td width="257" style="border-width: medium 1px 1px medium; border-style: none solid solid none; border-color: currentcolor windowtext windowtext currentcolor; background: rgb(218, 233, 247); padding: 0px 7px; word-break: break-all;"><p>Test settings and actual duration should be recorded in the report</p></td></tr><tr><td width="264" style="border-width: medium 1px 1px; border-style: none solid solid; border-color: currentcolor windowtext windowtext; border-image: initial; padding: 0px 7px; word-break: break-all;"><p>Current limitation during short interruptions under low impedance conditions</p></td><td width="250" style="border-width: medium 1px 1px medium; border-style: none solid solid none; border-color: currentcolor windowtext windowtext currentcolor; padding: 0px 7px; word-break: break-all;"><p>Prevents excessive current or</p><p>short-circuit risk</p></td><td width="257" style="border-width: medium 1px 1px medium; border-style: none solid solid none; border-color: currentcolor windowtext windowtext currentcolor; padding: 0px 7px; word-break: break-all;"><p>Test equipment capability and EUT protection conditions need to be confirmed</p></td></tr><tr><td width="264" style="border-width: medium 1px 1px; border-style: none solid solid; border-color: currentcolor windowtext windowtext; border-image: initial; background: rgb(218, 233, 247); padding: 0px 7px; word-break: break-all;"><p>Clarification of test generator specifications and verification</p></td><td width="250" style="border-width: medium 1px 1px medium; border-style: none solid solid none; border-color: currentcolor windowtext windowtext currentcolor; background: rgb(218, 233, 247); padding: 0px 7px; word-break: break-all;"><p>Provides clearer requirements for generator performance and&nbsp;</p><p>verification</p></td><td width="257" style="border-width: medium 1px 1px medium; border-style: none solid solid none; border-color: currentcolor windowtext windowtext currentcolor; background: rgb(218, 233, 247); padding: 0px 7px; word-break: break-all;"><p>Calibration or verification items may need to be reviewed</p></td></tr><tr><td width="264" style="border-width: medium 1px 1px; border-style: none solid solid; border-color: currentcolor windowtext windowtext; border-image: initial; padding: 0px 7px; word-break: break-all;"><p>Clarification of switching characteristics and inrush current verification load</p></td><td width="250" style="border-width: medium 1px 1px medium; border-style: none solid solid none; border-color: currentcolor windowtext windowtext currentcolor; padding: 0px 7px; word-break: break-all;"><p>Provides additional details&nbsp;</p><p>regarding load conditions</p></td><td width="257" style="border-width: medium 1px 1px medium; border-style: none solid solid none; border-color: currentcolor windowtext windowtext currentcolor; padding: 0px 7px; word-break: break-all;"><p>The laboratory should confirm whether the verification load meets the new requirements</p></td></tr><tr><td width="264" style="border-width: medium 1px 1px; border-style: none solid solid; border-color: currentcolor windowtext windowtext; border-image: initial; background: rgb(218, 233, 247); padding: 0px 7px; word-break: break-all;"><p>Clarification of evaluation and test report requirements</p></td><td width="250" style="border-width: medium 1px 1px medium; border-style: none solid solid none; border-color: currentcolor windowtext windowtext currentcolor; background: rgb(218, 233, 247); padding: 0px 7px; word-break: break-all;"><p>Provides clearer requirements for result evaluation and reporting</p></td><td width="257" style="border-width: medium 1px 1px medium; border-style: none solid solid none; border-color: currentcolor windowtext windowtext currentcolor; background: rgb(218, 233, 247); padding: 0px 7px; word-break: break-all;"><p>The report should include test level, duration, operating mode, and performance criteria</p></td></tr><tr><td width="264" style="border-width: medium 1px 1px; border-style: none solid solid; border-color: currentcolor windowtext windowtext; border-image: initial; padding: 0px 7px; word-break: break-all;"><p>Addition of DC environment descriptions</p></td><td width="250" style="border-width: medium 1px 1px medium; border-style: none solid solid none; border-color: currentcolor windowtext windowtext currentcolor; padding: 0px 7px; word-break: break-all;"><p>Provides background information on DC networks</p></td><td width="257" style="border-width: medium 1px 1px medium; border-style: none solid solid none; border-color: currentcolor windowtext windowtext currentcolor; padding: 0px 7px; word-break: break-all;"><p>Useful for explaining DC system applications and test relevance</p></td></tr></tbody></table><p>&nbsp;</p><p><span style="color: rgb(0, 176, 240);"></span></p><hr/><p><span style="color: rgb(0, 176, 240);"><strong>5. Test Concept</strong></span><br/></p><p>This test is not a surge, EFT, or ripple test. It is intended to simulate DC power supply quality disturbances.</p><p>Typical causes include:</p><table cellspacing="0" cellpadding="0"><tbody><tr class="firstRow"><td width="171" valign="middle" style="border: 1px solid windowtext; background: rgb(0, 112, 192); padding: 0px 7px; word-break: break-all;" align="center"><p><strong><span style="color: rgb(255, 255, 255);">Phenomenon</span></strong></p></td><td width="576" valign="middle" style="border-width: 1px 1px 1px medium; border-style: solid solid solid none; border-color: windowtext windowtext windowtext currentcolor; border-image: initial; background: rgb(0, 112, 192); padding: 0px 7px; word-break: break-all;" align="center"><p><strong><span style="color: rgb(255, 255, 255);">Possible cause</span></strong></p></td></tr><tr><td width="165" valign="middle" style="border-width: medium 1px 1px; border-style: none solid solid; border-color: currentcolor windowtext windowtext; border-image: initial; padding: 0px 7px; word-break: break-all;" align="center"><p>DC voltage dip</p></td><td width="570" valign="top" style="border-width: medium 1px 1px medium; border-style: none solid solid none; border-color: currentcolor windowtext windowtext currentcolor; padding: 0px 7px; word-break: break-all;"><p>Large load startup, battery switching, or temporary DC bus voltage drop</p></td></tr><tr><td width="171" valign="middle" style="border-width: medium 1px 1px; border-style: none solid solid; border-color: currentcolor windowtext windowtext; border-image: initial; background: rgb(218, 233, 247); padding: 0px 7px; word-break: break-all;" align="center"><p>DC short interruption</p></td><td width="576" valign="top" style="border-width: medium 1px 1px medium; border-style: none solid solid none; border-color: currentcolor windowtext windowtext currentcolor; background: rgb(218, 233, 247); padding: 0px 7px; word-break: break-all;"><p>Power source switching, protection device operation, or contact interruption</p></td></tr><tr><td width="171" valign="middle" style="border-width: medium 1px 1px; border-style: none solid solid; border-color: currentcolor windowtext windowtext; border-image: initial; padding: 0px 7px; word-break: break-all;" align="center"><p>DC voltage variation</p></td><td width="576" valign="top" style="border-width: medium 1px 1px medium; border-style: none solid solid none; border-color: currentcolor windowtext windowtext currentcolor; padding: 0px 7px; word-break: break-all;"><p>Battery/rectifier switching, backup power transfer, or DC network voltage&nbsp;</p><p>regulation</p></td></tr></tbody></table><p>The following parameters normally need to be defined during the test:</p><p>1. Rated DC input voltage, Un</p><p>2. Test level, such as a percentage of Un or 0% Un</p><p>3. Duration；</p><p>4. Number of repetitions and interval</p><p>5. EUT operation mode；</p><p>6. Performance criteria, such as Criteria A, B, or C, or the criteria specified by the product standard</p><p>&nbsp;</p><hr/><p><span style="color: rgb(0, 176, 240);"><strong>6. Significance for 800 Vdc / HVDC Products</strong></span><br/></p><p>The 2026 edition is expected to address higher DC network voltages by increasing the output voltage capability of the test generator. This makes the standard more relevant to modern high-voltage DC systems, such as data center DC distribution, energy storage systems, power conversion equipment, and 800 Vdc architectures.</p><p>However, IEC 61000-4-29 is a basic EMC publication. It does not automatically mean that the test is mandatory for every product with a DC input. In practice, applicability should be determined based on the relevant product standard, product family standard, generic standard, or customer specification, such as EN IEC 61000-6-2, EN IEC 61000-6-4, EN 55011 / CISPR 11, EN 55032 / CISPR 32, or other dedicated product standards.</p><p><br/></p><hr/><p><span style="color: rgb(0, 176, 240);"><strong>7. Brief Conclusion</strong></span><br/></p><p>EN IEC 61000-4-29:2026 is an EMC immunity test standard for voltage dips, short interruptions, and voltage variations on DC input power ports.</p><p>The key focus of the 2026 edition is to address new DC power distribution environments, especially higher-voltage DC systems. It also clarifies test generator capability, duration tolerance, current limitation during short interruptions, inrush current verification, result evaluation, and test report requirements.</p><p>For products using 24 Vdc, 48 Vdc, 380 Vdc, 400 Vdc, 800 Vdc, or other DC input power systems, this standard is highly relevant when DC power port immunity is required by the applicable product standard, generic EMC standard, or customer specification.</p><p><br/></p></div>
</div>


</div>

<div style="float:right"><a href="industry.php"><img src=images/back.gif border=0></a><a href=#><img src=images/top_x.gif border=0></a></div>

</div>

</div>

 </div>




</div>
<div class="bommenu">
	<ul>
        <li><a href="product.php">Service Center</a>
    	<div>
        	<a href=product.php?cid=477>NCC RCB</a>        </div>
    </li>
        <li><a href="industry.php">Technical platform</a>
    	<div>
        	<a href=industry.php?cid=473>Mobile Communication</a><a href=industry.php?cid=479>BQB</a><a href=industry.php?cid=472>SAR / OTA</a><a href=industry.php?cid=480>IoT</a><a href=industry.php?cid=413>EMC</a><a href=industry.php?cid=424>RF</a><a href=industry.php?cid=474>Telecom</a><a href=industry.php?cid=425>Safety</a><a href=industry.php?cid=485>New Energy</a><a href=industry.php?cid=481>Other</a><a href=industry.php?cid=486>Information security</a>        </div>
    </li>
        <li><a href="zhengshu.php">Certificate</a>
    	<div>
        	<a href=zhengshu.php?cid=444>Certificate</a>        </div>
    </li>
        <li><a href="about.php">About BTL</a>
    	<div>
        	<a href=about.php?id=487>Group Profile</a><a href=about.php?id=73>Complaints process</a><a href=about.php?id=237>Declaration of impartiality</a>        </div>
    </li>
        <li><a href="join.php">Join us</a>
    	<div>
        	<a href=join.php?cid=428>Talent recruitment</a><a href=join.php?cid=429>Employees demeanor</a><a href=join.php?cid=449>The enterprise information</a>        </div>
    </li>
    		<li><p><img src="images/BTLewm.jpg" /></p><p>WeChat account</p></li>
    </ul>
</div>
<div class="end">
	<p><strong>LINK: </strong>
	<a href=https://www.globalcertificationforum.org/ target=_blank>GCF</a><a href=https://www.ptcrb.com/ target=_blank>PTCRB</a></p>
Copyright © 2008-2019 BTL Inc.  All Rights Reserved  ICP NO.18145055<a href="https://beian.miit.gov.cn" target="_blank">粤ICP备18145055号</a>&nbsp;&nbsp;技术支持：<a href="https://www.0769net.com/" target="_blank">东莞网站设计</a>
</div>
</body>
</html>